ARS Series Interface Options
Fraction Collector The ARS delivers samples to sterile vials in a fraction collector for post run analysis. Using Peltier temperature control, the fraction collector maintains temperature in a range of 4°C to 37°C. The standard rack supports 30 vials. Custom racks are available to meet individual requirements.
Nutrient Monitors The ARS supports nutrient monitors from several vendors that can provide analysis for glucose, lactate, glutamate, glutamine, sucrose, ammonium, potassium, ethanol, lactose, methanol, and chlorine.
HPLC Systems HPLC is one of the most widely used analytical tools in the biotech industry. The ARS can deliver sample to any HPLC system that supports a simple digital interface. Dependent on the operation, the ARS can function as the master controller or as a slave to the HPLC.
Cell Counters Groton Biosystems is developing interfaces to industry-standard cell counters to ensure rapid delivery of samples as well as the recording and handling of the results.
 
Minimum Sample Dead Volume (Typical)
Process Development 1/16" system (0.040 id.) 1.4 ml plus volume of connection to reactor
Pilot Plant/Production 1/4" system 40 ml plus volume of connection to reactor
1/2" system 160 ml plus volume of connection to reactor
 
Sample Wetted Surfaces
Process Development PEEK or 316 SS bodies with PTFE, Chemraz or EPDM valve diaphragms
Pilot Plant/Production 316 SS body, polishes from 11–38µin, plastic bonnet and PTFE or EPDM diaphragms
 
Sample Tubing Specification
Process Development 1/16" o.d. PEEK or 316 SS
Pilot Plant/Production 316 SS – dimensions to order
 
Reactor Connection
Process Development A Groton Biosystems Reactor Interface Module to Flownamics or equivalent in-situ probe connecting to 1/16" o.d. tubing (Probe specified, purchased, and supplied by customer)
Pilot Plant/Production Tri-clamp Reactor Interface Pneumatic Valve dimensioned to order. Flex or permanent mountings
 
Valve Actuators
Process Development Electric – controlled by ARS
Pilot Plant/Production Pneumatic (90 psi compressed air site supplied) air solenoid controlled by ARS
 
Valve Control
Process Development By ARS Control System
Pilot Plant/Production Main reactor valve by Reactor Control System
All other valves by ARS Control System Optional – All valves controlled by ARS
 
Cleaning Systems (CIP)
  Fully automated for development and production models.
Cleaning chemistry to conform to customer specification.
Sodium hydroxide, hypochlorite, or standard detergents compatible
 
Sterilization Systems
Fully automated for development and production models
Process Development Chemical sterilization systems utilize ethanol, formalin, or hypochlorite
Pilot Plant/Production Large scale production ARS systems (1/2"+) support SIP (steam site supplied.)
 
Reagent Consumption per Sterilization Cycle for Chemical Sterilization Processes (Typical)
Process Development 15 ml
Pilot Plant/Production 100 ml
 
Reagent Consumption per Cleaning Cycle (Typical)
CLEANING REAGENT RINSE/NEUTRALIZATION REAGENT
Process Development 5 ml Process Development 100 ml
Pilot Plant/Production 150 ml Pilot Plant/Production 900 ml
 
Control System
Development/Production ARS Control System
(Upgrades of ARS Control System to GPA fraction collection and/or other assay systems available.)